GFG Instrumentation CS 21 Refrigerant
Series |
GFG CS 21
GFG CS 21 with
External Sensor
|
GFG's CS 21 Refrigerant Series fixed
transmitters feature a fast responding, long-life chemosorption
(solid state) sensor and 4 to 20mA output to a controller. The CS
21 is designed for non-explosive areas. Power requirements: 10 -32
VDC, 3-Wire 18 AWG shielded.
Ordering Information |
Part Number |
Description |
List Price
(U.S. $) |
2214019 |
GFG Instrumentation CS 21 Series Fixed Transmitter
for CFC-113 (CCl2FCCl2F2), (0)
30 to 5,000 ppm. |
|
2214021 |
GFG Instrumentation CS 21 Series Fixed Transmitter
for HFC-143a (CF3CH3F), (0) 30 to 5,000
ppm. |
|
2214020 |
GFG Instrumentation CS 21 Series Fixed Transmitter
for HFC-134a (CF3CH2F), (0) 30 to 5,000
ppm. |
|
2214018 |
GFG Instrumentation CS 21 Series Fixed Transmitter
for HFC-23 (CHF3), (0) 30 to 1,000 ppm. |
|
2214016 |
GFG Instrumentation CS 21 Series Fixed Transmitter
for HCFC-21 (CHCl2F), (0) 30 to 5,000 ppm. |
|
2214017 |
GFG Instrumentation CS 21 Series Fixed Transmitter
for HCFC-22 (CHClF2), (0) 20 to 1,000 ppm.
|
|
2216XXX |
External Sensor Cable (Six Foot) |
|
|
GFG Instrumentation
CI 21 Ammonia Gas Sensor
Assembly |
GFG Instrumentation
CI 21
Ammonia Gas
Sensor Assembly |
GFG Instrumentation CI 21 Ammonia Gas Sensor
Assembly offers long sensor life, a wide operating temperature range
(-35o to +130oF), extremely fast response (T90 <10
seconds, low cross sensitivity, a long-life sensor (expected
sensor life of >3 years) and a 4 to 20 mA output.
Ordering Information |
Part Number |
Description |
List Price
(U.S. $) |
2211004 |
GFG Instrumentation CI 21 Ammonia Sensor
Assembly with an internal sensor and a detection range
of 0 (20) to 200 ppm. |
|
2211005 |
GFG Instrumentation CI 21 Ammonia Sensor
Assembly with an internal sensor and a detection range
of 0 (30) to 1,000 ppm. |
|
2211006 |
GFG Instrumentation CI 21 Ammonia Sensor
Assembly with an internal sensor and a detection range
of 0 (30) to 10,000 ppm. |
|
2212004 |
GFG Instrumentation CI 21 Ammonia Sensor
Assembly with an external sensor and a detection range
of 0 (20) to 200 ppm. |
|
2212005 |
GFG Instrumentation CI 21 Ammonia Sensor
Assembly with an external sensor and a detection range
of 0 (30) to 1,000 ppm. |
|
2212006 |
GFG Instrumentation CI 21 Ammonia Sensor
Assembly with an external sensor and a detection range
of 0 (30) to 10,000 ppm. |
|
|
GFG Instrumentation EC 30 AutoCal Series |
GFG EC 30 Series
for Oxygen and
Toxic Gases
GFG EC 30 Series Optional Remote Calibration Plug
and Display Module
|
GFG's EC 30 AutoCal Series is an
advanced transmitter for the detection of oxygen and toxic gases.
This Smart Area Monitor features an explosion proof housing with a
stainless steel sensor cover that makes the EC 30 Series suitable for
the harshest environments. The EC 30 Series consists of the EC 35
and the EC 36. The EC 35 is a fixed single gas transmitter with
digital display, non-intrusive AutoCal calibration, explosion proof
housing, and 4
to 20 mA output to PLC or controller. In addition to the features
of the EC 35, The EC 36 adds on-board relays (two (2) alarms and one (1)
fault), a back lit display, and status LEDs.
Ordering Information |
Part Number |
Description |
List Price
(U.S. $) |
3511-200 |
GFG EC 35 for Ammonia 0 - 200
ppm, (-40 oF to +105 oF). |
|
3511-500 |
GFG EC 35 for
Ammonia 0 - 500 ppm, (-40oF to +105 oF). |
|
3511-200SE |
GFG EC 35 for Ammonia 0 - 200
ppm, (-4oF to +105 oF). |
|
3511-500SE |
GFG EC 35 for Ammonia 0 -
500 ppm, (-4oF to +105 oF). |
|
3611-200 |
GFG EC 36 for Ammonia 0 - 200
ppm, (-40 oF to +105 oF). |
|
3611-500 |
GFG EC 36 for Ammonia 0 -
500 ppm, (-40oF to +105 oF). |
|
3611-200SE |
GFG EC 36 for Ammonia 0 - 200
ppm, (-4oF to +105 oF). |
|
3611-500SE |
GFG EC 36 for Ammonia 0 -
500 ppm, (-4oF to +105 oF). |
|
2350230 |
RP 30 Remote Calibration Plug |
|
2350231 |
RC 30 Remote Calibration Display
with Three (3) Feet of Cable |
|
|
GFG Instrumentation
Dynagard AutoCal Series
|
GFG Dynagard for
Oxygen
and Toxic Gases
|
The Dynagard AutoCal Series single point
detection systems accurately measure toxic gas and oxygen levels.
Dynagard offers a large back lit LED display, an internal horn, linear 4
to 20 mA output, Auto Cal calibration, and smart sensor technology,
on-board relays, and 110 VAC or 24 VDC power supply.
Ordering Information |
Part Number |
Description |
List Price
(U.S. $) |
3711-200 |
GFG Dynagard for Ammonia 0 - 200
ppm, (-40 oF to +105 oF). |
|
3711-500 |
GFG Dynagard for Ammonia 0 -
500 ppm, (-40oF to +105 oF). |
|
3711-200SE |
GFG Dynagard for Ammonia 0 - 200
ppm, (-4oF to +105 oF). |
|
3711-500SE |
GFG Dynagard for Ammonia 0 -
500 ppm, (-4oF to +105 oF). |
|
|
GFG Instrumentation
EC 23 Series Sensor/Transmitter |
Coming Soon |
The EC 23 Series is an economical, no
frills electrochemical sensor/transmitter for the detection of toxic gases.
EC 23 series transmitters offer a linear 4
to 20 mA output signal to a PLC or controller. In addition to
ammonia, a variety of other electrochemical sensors are available.
Ordering Information |
Part Number |
Description |
List Price
(U.S. $) |
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: The -40 oF
ammonia sensor used on the EC 35, EC 36, Dynagard, and EC 22N is not
recommended for areas where there is a potential for background carbon
monoxide or alcohols. |
|